Is R-410A being phased out?

New equipment has moved to different refrigerants. The system you already own is still legal and serviceable.

Quick answer

Yes, for new equipment. Under EPA rules issued under the AIM Act, residential and light commercial air conditioners and heat pumps manufactured or imported on or after January 1, 2025 can no longer use R-410A. Newly made systems use R-454B or R-32 instead. R-410A equipment that was already built or imported before 2025 can still be installed, under an EPA rule that took effect July 27, 2026. Existing R-410A systems are not banned. You can keep running, repairing, and recharging one, and R-410A is still produced for service, although national production of this class of refrigerants is being reduced in steps.

What changed, and when

R-410A is an HFC refrigerant. It doesn’t harm the ozone layer, but it is a strong greenhouse gas, with a global warming potential (GWP) of about 2,088 times that of carbon dioxide. The American Innovation and Manufacturing (AIM) Act of 2020 directed EPA to phase down HFCs, and EPA’s rules under it set a GWP limit of 700 for new residential and light commercial air conditioning and heat pump equipment.

  • January 1, 2025: new residential and light commercial AC and heat pump equipment can no longer be manufactured or imported with a refrigerant above the 700 GWP limit. That rules out R-410A.
  • January 1, 2026 (since removed): EPA first set this as the last day to install R-410A equipment built before 2025. A final rule effective July 27, 2026 removed that deadline, so existing inventory can still be installed.
  • Through 2036: national HFC production and import are stepped down to 15 percent of the baseline level.

The replacements: R-454B and R-32

Manufacturers chose one of two refrigerants for new equipment. R-454B has a GWP of about 466 and R-32 about 675, both under the limit. From the homeowner’s side they work the same way R-410A does: same kind of outdoor unit, same indoor coil, same thermostat.

The real difference is their safety classification. R-410A is rated A1, nonflammable. R-454B and R-32 are rated A2L, which means lower flammability. For that reason the equipment is built for them specifically, and they can’t be added to an older system.

If you own an R-410A system

  • You can keep it. Nothing requires replacement.
  • It can be repaired and recharged with R-410A.
  • Expect the refrigerant to cost more as years pass, which makes it more worthwhile to find and fix leaks than to top off repeatedly.
  • If the outdoor unit fails beyond repair, the replacement will usually be an R-454B or R-32 system, and the indoor coil is generally replaced with it. Matching R-410A equipment built before 2025 can sometimes still be found, but supply is shrinking.

If you own an R-22 system

You are one refrigerant generation further back. R-22 has not been produced or imported since January 1, 2020, and what is left is reclaimed or previously stockpiled supply at a high price. An R-22 system that runs without leaking is fine to keep. Once it develops a refrigerant leak, the numbers usually favor replacement. See repair or replace an old AC.

If you are buying a new system

Most new systems quoted today use R-454B or R-32. Leftover R-410A equipment built before 2025 can still be legally installed, and it is sometimes offered at a lower price. If a quote uses R-410A, know that you are buying into a refrigerant whose supply is being cut, which makes future leak repairs more expensive. Ask which refrigerant every quote uses, and make sure it covers a matched indoor coil or air handler. This is also the time to look at SEER2 ratings and sizing. Our installation page lists what a complete quote should state.

Not sure what you have or what your options are? Call (210) 687-7376. Free phone consultation.

Follow-up questions

Do I have to replace my R-410A air conditioner?
No. The rules restrict what can be manufactured and installed new. They do not require anyone to remove or stop using an existing system, and R-410A remains available for servicing it.
Can R-454B or R-32 be put into my R-410A system?
No. They are not drop-in replacements. R-454B and R-32 are classed as mildly flammable, and equipment has to be designed and listed for them. An R-410A system is serviced with R-410A.
Will R-410A get more expensive?
Probably, over time. The AIM Act directs EPA to cut national production and import of HFC refrigerants, the family that includes R-410A, by 85 percent by 2036. Less supply with millions of systems still in service points toward higher prices, as happened with R-22. Nobody can tell you how much or how fast.
Is R-454B safe?
R-454B and R-32 carry the A2L safety classification, which means low toxicity and lower flammability. They are harder to ignite than fuels like propane and burn slowly. Equipment built for them is designed and tested around that property, and installation follows updated safety standards.
What happened to R-22?
R-22, often called Freon, was the standard refrigerant before R-410A. It was phased out because it damages the ozone layer. New equipment charged with R-22 stopped being made in 2010, and production and import of the refrigerant ended on January 1, 2020. Only reclaimed, recovered, and previously stockpiled R-22 is available now, and EPA does not require you to convert or replace an R-22 system.
Can a contractor still install a new R-410A system?
Yes, if the equipment was manufactured or imported before January 1, 2025. EPA originally set January 1, 2026 as the last day to install that leftover stock, then removed the deadline in a rule that took effect July 27, 2026. No new R-410A residential equipment is being made, so this only covers inventory that already exists.
Which refrigerant does my system use?
Check the data plate on the outdoor unit. In general, systems installed before 2010 use R-22, systems from 2010 through 2024 use R-410A, and most systems installed since 2025 use R-454B or R-32. Some newer installs use leftover R-410A equipment built before 2025.