Quick answer
Under U.S. Department of Energy standards that took effect January 1, 2023, a new split-system central air conditioner installed in Texas must be rated at least 14.3 SEER2 if its capacity is under 45,000 Btu/h, or 13.8 SEER2 if it is 45,000 Btu/h or larger. New split-system heat pumps must be at least 14.3 SEER2 and 7.5 HSPF2. Texas falls in DOE’s Southeast region, where the standard is enforced by installation date. Systems already installed are not affected.
The minimums that apply in Texas
The Department of Energy sets minimum efficiency standards for residential central air conditioners and heat pumps. The current ones took effect on January 1, 2023, and they differ by region. Texas is in the Southeast region.
- Split-system air conditioner under 45,000 Btu/h (under 3.75 tons): 14.3 SEER2 minimum
- Split-system air conditioner of 45,000 Btu/h or more: 13.8 SEER2 minimum
- Split-system heat pump, any region: 14.3 SEER2 and 7.5 HSPF2 minimum
A split system is the usual setup in a house: an outdoor unit connected by refrigerant lines to an indoor coil or air handler. Single-package units, where everything sits in one cabinet outdoors, have their own minimums.
Installation date, not manufacture date
In the northern states, the air conditioner standard applies to when equipment was manufactured, so older stock can still be installed there. In the Southeast and Southwest regions it applies to when the air conditioner is installed. An air conditioner that doesn’t meet the regional minimum can’t legally be installed in Texas, whenever it was built. This matters if someone offers you a deal on leftover equipment.
SEER versus SEER2
SEER stands for Seasonal Energy Efficiency Ratio: the cooling a system delivers over a typical season, divided by the electricity it uses. Higher is better. SEER2 is the same idea measured with a tougher test that adds resistance to represent real ductwork. The result is a slightly lower number for the same equipment.
- 14.3 SEER2 is roughly 15 SEER
- 13.8 SEER2 is roughly 14.5 SEER
Before 2023 the minimum for air conditioners in this region was 14 SEER, so the change raised the floor by about one SEER point. When you compare an old quote or an older unit’s label with a new one, check which rating you are looking at.
Is it worth going above the minimum?
Efficiency pays back in proportion to run time, and few places in the country run an air conditioner as many hours as South Texas. A higher SEER2 system uses less electricity for the same cooling in every one of those hours. Whether the savings cover the higher price depends on the price gap between models, your electric rate, and how long you will own the house. Ask for prices at two efficiency levels so you can see the gap.
Remember that the rating is for a matched outdoor and indoor unit installed correctly. Leaky ducts, a wrong refrigerant charge, or a mismatched indoor coil will keep any system from performing to its label. See what goes into a good installation.
Where to find the rating
The yellow EnergyGuide label on new equipment shows the SEER2 rating. The official rating for a specific pairing of outdoor and indoor unit is listed in the AHRI Directory of Certified Product Performance, and a contractor can give you the AHRI reference number for the system quoted.
Questions about a quote? Call (210) 687-7376. Free phone consultation.
Follow-up questions
- What is the difference between SEER and SEER2?
- Both measure cooling output over a season divided by the electricity used. SEER2 comes from a newer DOE test procedure, in use since 2023, that runs the equipment against higher duct pressure to better reflect a real installed system. The same unit scores a little lower in SEER2 than in SEER. A 14.3 SEER2 rating is about equal to 15 SEER.
- Is my old 10 or 13 SEER air conditioner illegal now?
- No. The standards apply to new equipment being installed. You can keep using and repairing an existing system for as long as it lasts.
- What is a good SEER2 rating for San Antonio?
- Anything at or above the 14.3 SEER2 minimum is legal. Because air conditioners here run for so much of the year, stepping up a level or two pays back faster than it would in a cooler climate. The right level depends on the price difference, your electric rate, and how long you expect to stay in the house.
- Does a higher SEER2 unit cool the house better?
- Not by itself. SEER2 measures efficiency, not cooling power. Higher-rated models often have two-stage or variable-speed compressors, though, and those run longer at low output, which gives more even temperatures and better humidity control.
- What is HSPF2?
- Heating Seasonal Performance Factor 2 is the heating efficiency rating for heat pumps, measured under the same updated test procedure as SEER2. The federal minimum for new split-system heat pumps is 7.5 HSPF2.
- What is EER2, and does Texas have an EER2 requirement?
- EER2 measures efficiency at one fixed hot-weather test condition instead of across a season. DOE sets minimum EER2 levels for air conditioners in its Southwest region, which is Arizona, California, Nevada, and New Mexico. Texas is in the Southeast region, where the federal minimum for air conditioners is stated in SEER2.